preform · pf-03

Short shot (incomplete fill)

Cause

Low injection pressure, insufficient material, or blocked gate prevents full cavity fill.

Corrective action

Increase injection pressure/speed, check shot size, clear/clean the gate, verify melt temperature.

Diagnosis guide: Short shot (incomplete fill)

What you will see

Part of the preform did not fill: a rounded or missing thread start, support ring or sealing surface, or in severe cases a short body. Affected preforms weigh less than the SKU nominal.

Likely causes

  • Shot size or injection pressure too low at the preform plant
  • A partly blocked gate or hot-runner nozzle on one cavity
  • Melt temperature too low for the melt to fill thin sections
  • A blocked cavity vent trapping air at the end of fill

Do this first

STOP receiving. Inspect and weigh 30 preforms from the carton.

How to diagnose it

  1. Inspect the neck, thread start and support ring of 30 preforms under a magnifier
  2. Weigh the same 30 preforms on a 0.01 g balance and compare with the SKU spec sheet nominal
  3. Read the cavity number on every short preform: one cavity repeating points to a blocked gate or vent
  4. Apply the Go/No-Go neck gauge to the suspect preforms

How to fix it

  1. Quarantine the lot
  2. Contact Delta with photos, weights and cavity numbers
  3. Sort the lot only with Delta's agreement; a short neck finish will not seal

Further reading

Need this issue solved on your line?

Talk to our engineersBrowse PET preforms →