Pearlescence (stress whitening)
Cause
Over-stretching cold preform or excessive orientation causes pearly white appearance.
Corrective action
Raise preform temperature, reduce stretch ratio, balance pre-blow; verify TSR within 8–12 range.
Where it shows — and how we check for it
● quality issue

Seeing this on your line? Send our team a photo on WhatsApp — the message already names the defect.
Send a photo on WhatsAppDiagnose it step by stepDiagnosis guide: Pearlescence / white haze in body
What you will see
Body wall shows pearly white shimmer or milky haze, particularly visible against dark backgrounds. The bottle is structurally intact but loses optical clarity. Typically appears uniformly across body or in stretched zones.
Likely causes
- Preform body too cold for its stretch — PET stretched below its orientation window tears into micro-voids (stress whitening)
- Stretch ratio too high for the bottle — the preform is too short or too slim, so the wall is over-stretched even at a normal temperature
- Stretch rod too fast or pre-blow too late — one zone is stretched before the rest of the wall is inflated
- Lamp output dropped (ageing lamps or a failed lamp) — the oven no longer delivers the heat the recipe assumes
- Cold or damp preforms fed straight from storage — condensation and a cold core cool the wall unevenly
Do this first
Increase preform body temperature by 2-3°C and rerun a 30-bottle sample.
How to diagnose it
- Pearlescence is silvery and strongest in the most-stretched zone; a milky haze that is worse where stretch is LOW is overheating instead — check which one you have
- Inspect the last 30 bottles: uniform across the body, or one zone or one cavity only?
- Measure preform surface temperature at the oven exit with an IR pyrometer and compare with the recipe
- Check the lamp-current monitor / lamp hours against the lamp maker's rated life; look for a dead lamp in the zone that whitens
- Compare the bottle's stretch ratios (TSR 8–12 typical) in the Preform Engineering tool — above the band, the preform itself is the cause
How to fix it
- Raise the lamp power of the whitening zone by 3–5% (or overall heat 2–3 °C) and run a 30-bottle sample
- If it persists, start pre-blow slightly earlier or reduce stretch-rod speed by 0.1 m/s so the wall inflates as it stretches
- Replace dead or weak lamps and re-check the zone profile with the pyrometer
- Condition preforms at plant temperature (typically 24 h) before loading; never feed cold or wet preforms
- If the stretch ratio is above the band at a correct temperature, ask Delta for a longer or wider preform for this bottle
